CONSTRUCTION DATA

 

RG174A/U

RG58C/U

RG213/U

RG59B/U

RG62A/U

Inner conductor


dia mm

FeCu 
7x0,16
CuSn
19x0,18
Cu 
7x0,75
FeCu 
0,58
FeCu 
0,64
Dielectric


dia mm

PE 
1,50
PE 
2,95
PE 
7,25
PE 
3,70
PEA 
3,70
Screen: 
Braid 
Braid coverage 

 %
dia mm


CuSn 
88
1,90

CuSn
94
3,45

Cu
97
8,00

Cu
94
4,30

Cu
94
4,30
Outer Sheath


dia mm

PVC II
2,80 
PVC II
5,00
PVC II
10,30
PVC II
6,15
PVC II
6,15
Minimum bending radius:
single/repeated bendings


mm


15/30

25/50

50/100

30/60

30/60

ELECTRICAL DATA

 

         
Impedance

Ohm

 

50+/-2

 

50+/-2

 

50+/-2

 

75+/-3

 

93+/-5
Capacitance

pF/m

101+/-2 100+/-2 100+/-2 66+/-2 43+/-2
Velocity ratio

%

66 66 66 66 85
Attenuation (at 20°C): 
at MHz 50


dB/100m


20,0

10,7

4,1

7,7

5,9
at MHz 200

dB/100m

42,5 23,5 9,0 16,0 12,0
at MHz 300

dB/100m

51,0 29,6 11,3 19,9 14,9
at MHz 500

dB/100m

65,0 39,9 15,3 26,2 19,3
at MHz 800

dB/100m

83,0 53,4 20,4 34,0 24,7
at MHz 1000

dB/100m

97,0 61,1 23,6 38,7 28,0
Structural Return Loss (SRL)
30-300 MHz 


dB 


>21

>26

>27

>28

>17
300-600 MHz 

dB 

>19 >25 >26 >25 >16
600-1000 MHz

dB 

>18 >24 >24 >23 >15
Screening effectiveness
30-1000 MHz


dB


>50

>55

>55

>55

>55
Inner conductor dc resistance

Ohm/km

290 38,5 6,5 158 130
Outer conductor dc resistance

Ohm/km

42 16,5 4,5 11 10,5
Sheath spark testing

kV

2,0 5,0 5,0 3,0 5,0
Maximum power at: 
100 MHz 


W


50

200

830

300

250
400 MHz

W

25 60 320 135 90
1000 MHz

W

15 35 180 75 45
Copper weight

Kg/km

4,9 16,8 77,3 22,3 22,7
Cable weigth

Kg/km

12,3 36,7 156,1 52,5 50,0
PACKING
unit length 


m


100

150

100

100

100
model

No.

3 8B 9A 8A 8A
Specification conformity:
MIL-C-17

 


119F 

28C 

74C 

29C 

30D